huawei-cloud-ascend-command

Huawei Ascend NPU natural language management skill, supporting both local direct connection and SSH remote modes. Provides comprehensive npu-smi command capabilities including device queries, configuration management, firmware upgrade, vNPU virtualization, certificate management, and compute power testing (FLOPS). Enables remote management and monitoring of Ascend NPU devices with real-time metrics tracking. Use this skill when the user wants to: (1) query NPU device status and health, (2) monitor temperature, power, memory/HBM utilization, (3) configure ECC settings and fan modes, (4) perform firmware upgrades or rollbacks, (5) manage vNPU virtualization, (6) run compute power tests, (7) check certificate information. Trigger: user mentions 'npu', 'ascend', 'NPU', 'Ascend', 'temperature', 'power', 'HBM', 'firmware', 'upgrade', 'vNPU', 'virtualization', 'certificate', 'FLOPS', 'compute', 'health', 'memory', 'utilization', 'ECC', 'fan', '昇腾', '昇腾卡', '昇腾状态', '显存', '算力', '设备查询', 'NPU监控'

How do I install this agent skill?

npx skills add https://github.com/huaweicloud/huaweicloud-skills --skill huawei-cloud-ascend-command
view source ↗

Is this agent skill safe to install?

  • Gen Agent Trust Hubpass

    The skill is a professional management utility for Huawei Ascend NPU devices, providing comprehensive monitoring and configuration capabilities. It safely handles sensitive hardware operations through confirmation gates and follows security best practices for credential management, using localized command execution via secure system calls (shell=False). No malicious patterns, obfuscation, or data exfiltration vectors were identified during analysis.

  • Socketwarn

    1 alert: gptAnomaly

  • Snykpass

    Risk: LOW · No issues

What does this agent skill do?

Natural language command translation and execution for Huawei Ascend NPU devices: device queries, configuration management, firmware upgrade, vNPU virtualization, certificate management, and compute power testing.

Overview

Translates natural language requests into npu-smi / ascend-dmi commands on Huawei Ascend NPU devices, over either a local direct connection or an SSH remote session. This is a stateless, operational skill: it stores no credentials, device state or conversation history between invocations.

Capabilities: device queries (health, temperature, power, HBM, ECC, topology) · configuration (ECC, fan mode/speed) · firmware version / upgrade / activate / rollback · vNPU virtualization · TLS certificate management · FLOPS testing.

Orchestration: the Agent invokes this skill alongside others when a task needs them — for example a general-purpose SSH remote-operations skill (disk, Docker, logs, processes) or a model-deployment skill whose NPU state is monitored after deploy. Skills never call each other directly; the Agent selects and chains them from user intent. See references/architecture.md.

Prerequisites

RequirementDetail
Python3.8+ (python3 --version)
Local modenpu-smi (CANN) on the local machine; ascend-dmi additionally for FLOPS tests
SSH remote modeparamiko — install with pip install -r requirements.txt (paramiko>=2.11,<4)
Target hostReachable network, running sshd, password authentication enabled
  • Local mode needs no Python package beyond the standard library.
  • SSH mode needs paramiko; it is imported lazily, so local mode still works when it is absent.
  • The target machine must have CANN/npu-smi installed — run npu-smi info there once to confirm.
  • Security: never read, echo or print password values; never ask the user to paste a password into the conversation; read credentials only from the --password command-line argument.

Core Workflow

  1. Parse the user intent and normalize Chinese trigger words (触发词: 温度 / 功耗 / 显存 / 算力 / 固件 / 虚拟化 / 风扇 / 启用 / 禁用 …) to English.
  2. Direct passthrough first: if the input starts with npu-smi, execute it verbatim — this precedes natural-language routing, so npu-smi info -l keeps its -l.
  3. Route the natural-language request to a handler and resolve the device target (NPU0 Chip0), defaulting to NPU 0 / Chip 0.
  4. Read-only queries execute immediately and are formatted for the user.
  5. Write operations print a confirmation gate and wait for confirm / 确认 (or cancel / 取消) before executing — see Parameter Confirmation.
  6. Any failure returns a structured [ERROR] NPU-* response; a Python traceback is never shown.
python3 scripts/main.py --command "NPU health check"                                   # one-shot
python3 scripts/main.py --command "查看NPU温度"                                          # Chinese trigger words
python3 scripts/main.py --command "NPU list" --host <ip> --user root --password <pwd>  # SSH remote
python3 scripts/main.py                                                                # interactive

Core Commands

IntentExample inputUnderlying command
List devicesNPU listnpu-smi info -l
Full / card infoNPU infonpu-smi info (full NPU information)
Card / chip mappingNPU chip mapping, chip listnpu-smi info -m (card-to-chip mapping)
Direct passthroughany input starting with npu-smi, e.g. npu-smi info -t boardexecuted verbatim, exactly as typed — passthrough takes precedence over natural-language routing
Health checkNPU health checknpu-smi info -t health -i 0
Temperature / power / memory / usageNPU temperature, 功耗, 显存npu-smi info -t temp | power | memory | usages -i 0 -c 0
ECC direction (mandatory)set ECC enable, disable ECCnpu-smi set -t ecc-enable -i 0 -c 0 -d 1 | 0 (confirmation)
Fan modeset fan auto, set fan manualnpu-smi set -t pwm-mode -d 1 | 0 (confirmation)
Fan speedset fan speed 70npu-smi set -t pwm-duty-ratio -d 70 (confirmation)
Firmware version / uploadfirmware version, upgrade firmwarenpu-smi upgrade -b mcu -i 0 / upgrade -t mcu -i 0 -f <file>.hpm (confirmation)
Firmware activateactivate firmware, activate upgrade mcu NPU0npu-smi upgrade -a <component> -i 0 (confirmation)
Firmware rollbackrollback firmwarenpu-smi upgrade -a rollback -i <npu_id> (confirmation)
vNPUvNPU info, template info, create vNPU, destroy vNPUnpu-smi info -t info-vnpu | template-info …, set -t create-vnpu | destroy-vnpu … (confirmation)
Certificatecertificate info, cert expirationnpu-smi info -t tls-cert | tls-cert-period -i 0 -c 0
FLOPSFLOPS test, FP32 FLOPS, all devices FLOPSascend-dmi -f -d <n> -t <fp16|fp32|bf16|int8|hf32> -q; multi-device runs async in parallel

The complete natural-language → command mapping lives in references/command-mapping.md.

Parameter Confirmation

ParameterRequiredDescription
--commandYes (one-shot)Natural language request, or a direct npu-smi command
--hostSSH modeRemote host IP address / hostname
--user, --passwordSSH modeSSH credentials (password authentication only)

Read-only queries never prompt. These write operations always print their exact effect and wait for confirm / 确认 before executing:

  • ECC enable/disable — the direction (enable / disable) is mandatory; set ECC with no direction is answered with a clarification question and nothing is executed.
  • Fan mode / fan speed — set fan with neither auto / manual nor a speed value is answered with a clarification question; it never defaults to a speed.
  • Firmware upload / activate / rollback — rollback may be unsupported by some devices.
  • vNPU create / destroy.
  • Certificate management.

Output Format

Query results are human-readable text, optionally followed by the structured JSON envelope:

{"status": "success", "command": "npu-smi info -l", "description": "List all NPU devices"}

Errors use exactly three lines, with CODE taken from the error-code contract below:

[ERROR] <CODE>
Message: <error-description>
Suggestion: <troubleshooting-tip>

Error Handling & Stability

Error-code contract. One code per failure class, so "wrong credentials", "wrong host" and "the remote host really has no NPU" stay distinguishable:

CodeMeaningTypical suggestion
NPU-SSH-AUTHSSH authentication failedcheck --user / --password, account lockout, password login allowed
NPU-SSH-UNREACHABLEhost unreachable, port refused or connect timeoutcheck host, port 22, network, security group, sshd
NPU-SSH-ERRORother SSH-level failureretry once, then inspect sshd logs on the target
NPU-CMD-NOT-FOUNDnpu-smi / ascend-dmi not installed or not on PATHinstall CANN/npu-smi on the target, or use --host for SSH mode
NPU-CMD-FAILEDcommand ran but exited non-zeroinspect the reported exit code and stderr summary
NPU-TIMEOUTcommand exceeded its timeoutcheck device load, retry once if the condition was transient
NPU-UNEXPECTEDunclassified fallbackcheck the command and environment, then retry

Retry policy. Only transient failures are retried: a failing SSH connect/execute is retried once after the connection is closed, i.e. at most 2 attempts in total (worst-case wait ≈ 2 × connect timeout). Authentication failures, command_not_found, non-zero exits and timeouts are not retried blindly. Retries are always bounded and never fan out (no retry storm); a failed write is never silently re-sent.

Timeouts. SSH connection timeout 10s; a single local/remote command 60s; FLOPS tests up to 120s. Exceeding a timeout returns [ERROR] NPU-TIMEOUT with a suggestion instead of hanging.

Degradation. Every layer degrades to a friendly message rather than a traceback: missing npu-smi → NPU-CMD-NOT-FOUND; missing ascend-dmi → "ascend-dmi not found" for that FLOPS test only; missing paramiko or a failed SSH connection → a connection error, never "No NPU devices found". handle_command(None), non-string and empty input return the help listing instead of raising. See references/troubleshooting.md.

Idempotency. Queries (list, info, health, temperature, …) are read-only and safe to repeat. Writes (ECC, fan, firmware, vNPU, certificate) always pass the confirmation gate, execute exactly once, and are never auto-replayed after a failure — re-issue them explicitly if needed.

Boundary conditions.

  • No NPU hardware / no npu-smi locally → friendly NPU-CMD-NOT-FOUND, not a stack trace.
  • SSH authentication failure, unreachable host, and a reachable host with genuinely zero devices must remain three distinct outcomes; a connection error is never parsed as an empty device list.
  • Empty command output → an explicit "no data / no devices" message, never a crash.
  • Chinese input (for example 查看NPU温度) is normalized to English before routing.
  • Multi-turn state is limited to the pending confirmation of the current invocation; nothing is persisted, so every invocation starts clean.

Dependencies. Local mode: npu-smi (CANN), plus ascend-dmi for FLOPS only — no Python package required. SSH mode: paramiko (pip install -r requirements.txt). When a dependency is missing, report its error code and suggestion; never invent a fallback command.

Verification Method

  1. python3 --version → 3.8+.
  2. python3 scripts/main.py --command "NPU list" → a device table, or a friendly NPU-CMD-NOT-FOUND when npu-smi is absent (never a traceback).
  3. python3 scripts/main.py --host <ascend-ip> --user root --password <pwd> --command "NPU health check" → remote status; a wrong host or password must yield NPU-SSH-*, not "No NPU devices found".

The full reproducible matrix (Chinese inputs, direct npu-smi passthrough, confirmation gates, rollback) is in references/verification-method.md.

Troubleshooting

  • Command not recognized → use a supported keyword; Chinese trigger words are normalized, but unsupported wording returns the help listing.
  • SSH connection failed → follow the [ERROR] NPU-* code: credentials and account state for NPU-SSH-AUTH, host / port / network / sshd for NPU-SSH-UNREACHABLE.
  • npu-smi not available → install CANN/npu-smi on the target machine and check LD_LIBRARY_PATH.

Error codes and per-code diagnosis steps: references/troubleshooting.md.

Notes & Limitations

  • Sensitive operations always require confirmation; blocked commands cannot be bypassed; passwords are held in memory for the session only.
  • Requires npu-smi (or ascend-dmi for FLOPS) on the target machine; SSH uses password authentication only (no interactive prompt).
  • Verify a single card before batch operations, and watch temperature / HBM usage to avoid OOM.
  • Architecture, Agent orchestration flow, script files and directory layout: references/architecture.md.

References

DocumentDescription
architecture.mdSystem architecture, Agent orchestration flow, stateless rules, script files and directory layout
command-mapping.mdComplete natural-language → npu-smi / ascend-dmi command mapping, including fan mode/speed and firmware rollback
acceptance-criteria.mdAcceptance criteria for skill validation
verification-method.mdReproducible verification steps and test methods
troubleshooting.mdError codes and troubleshooting guide
device-queries.mdDevice queries command reference
configuration.mdECC and fan configuration reference
firmware-upgrade.mdFirmware version, upgrade, activate and rollback reference
virtualization.mdvNPU virtualization reference
certificate-management.mdCertificate management reference
iam-policies.mdIAM permission policy requirements (none — local/SSH operational skill)

Technical Support

Add the canonical catalog link to the repository README so users can inspect current installs and available audits. The publishing guide covers the complete discovery path.

<a href="https://skillzs.dev/skills/huaweicloud/huaweicloud-skills/huawei-cloud-ascend-command">View huawei-cloud-ascend-command on skillZs</a>